Thank you for purchasing a Hisense air conditioner. Before installing the appliance and using it, please read these instructions carefully and save them.
CONTENT:

Preparing for Use………………………………………….........2

Remote control preset remote control......2

Remote control backlight function...............................................3

Auto Restart Preset .......................................3

Designation of the working parts of the air conditioner .........................................3

Precautionary measures................................................ ........................four

Meaning of indicators .................................................................. ............................5

Emergency button .................................................................. ....................6

Remote control............................................... ........7

Meaning of symbols on the display............................................................... ........eight

Installing Batteries in the Remote Control....................................................... .eight

Remote control storage and usage ..............................................................9

Operating instructions for the remote control ............................................... ...........9

Temperature setting ................................................................ ........................ten

Switching on the air conditioner .................................................. .....................ten

Adjusting the Airflow Direction...............................................................10

SMART mode ..........................................................................11

Instrument Capabilities in SMART Mode .............................................................. ..12

Clock setting button CLOCK .................................................................. ...............12

Timer Mode ................................................................ ........................................12

How to set the timer to turn on .............................................................. ........12

How to cancel the wake-up timer .............................................................. .........13

Sleeping mode................................................ ................................................13

Super mode .................................................. ............................................13

Instrument care and maintenance .............................................................. ......fourteen

Instrument protection .................................................................. .......................................fifteen

Characteristics of the protective device .......................................................... ...fifteen

Characteristics of the heating mode .............................................................. .............fifteen

Possible Problems and Solutions .............................................................. ........16

Air conditioner installation instructions ............................................... ..17

Selecting a location for installation............................................................... ......................17

Installing the indoor unit .......................................................... ....................eighteen

Installing the outdoor unit............................................................... ......................23

Vacuumization of the system .................................................. ...............................23

Notes................................................... ...............................................24

PREPARATION FOR USE

Before using the air conditioner, be sure to check and preset as follows.
Remote Control Preset

The remote control may not be factory preset.

If you find flashing indicators on the display even after powering up the remote control, then you need to select the mode for the remote control yourself.

 Pressing any of the buttons while the indicator is flashing will pre-configure the remote control for heating-drying mode.

 Pressing any of the buttons while the LED is blinking will preset the console for cooling mode only.

The absence of flashing indicators will mean that the control panel has a preliminary automatic setting for heating-drying mode.

Note:

If the air conditioner you purchased has only cooling mode, and the remote control is pre-configured for heating-drying mode, this does not matter.

But if you have purchased an air conditioner with heating-drying mode, and the remote control is preset for cooling mode, then the heating function will be lost. You will need to pre-configure the remote control for heating-drying mode.

Backlight function (optional)

Hold any of the buttons on the remote for about 2 seconds to turn on the backlight. The backlight turns off automatically after about 10 seconds.

Note: The backlight is an optional (additional) function.
Automatic restart preset

The air conditioner has an automatic restart function. You can set or cancel this function during operation of the air conditioner.

• Hold down the emergency button (ON/OFF) for a few seconds. This function will be set after 2 beeps. If you heard 1 sound signal, then this function will be cancelled.

DESIGNATION OF WORKING PARTS OF THE AIR CONDITIONER

(outdoor and indoor units)




Air Intake- holes for air intake

Front panel - Front Panel

Display panel– display panel

Emergency panel– emergency control panel

Air outlet- air outlets

Vertical adjustment lover– regulators of the vertical direction of air

Horizontal adjustment lover– horizontal air direction regulators

Air filter– air filter

Remote control- remote control

Air Intake- holes for air intake

Pipes and power connection- connecting tubes and power cord

Drain Hose- drainage hose

Note: Water condensate will flow out in COOLING mode or DRY dehumidification mode

Air outlet- air outlets

Please note that the data in the description of the appearance of the device is based on the standard model. Accordingly, the forms may vary depending on the model you purchased.

PRECAUTIONARY MEASURES

The symbols in this manual have the following meanings:

Action prohibited.
Pay attention to such information.

Grounding is mandatory.

Warning: Improper handling may endanger health or result in serious injury.


Use the power according to the instructions on the device. Otherwise, there is a risk of serious damage or fire.



Protect the power switch and plug from dirt. Install the power plug correctly and firmly. Incorrect installation may result in electric shock or fire due to insufficient contact.



Do not use the power switch or pull on the power plug to turn off the appliance while it is in operation. This may cause a fire due to sparking.



Do not twist, pull or put pressure on the power cord, otherwise it may be damaged. A damaged power cord may cause a fire or electric shock.



Do not insert sticks or similar objects into the appliance. It may cause injury because the fan in the appliance rotates at high speed.



Prolonged and directed cooling is dangerous to your health. Make sure that cold air is distributed throughout the room.



First, turn off the device via the control panel and only then turn off the power to the device in case of malfunctions.



Do not repair the device yourself. Improper repairs may result in electric shock, etc.



Make sure that the air flow from the air conditioner does not reach gas burners and plates.



Do not touch the air conditioner control buttons with wet hands.



Do not place foreign objects on the outside of the air conditioner.



Grounding is the responsibility of the user of the instrument. The instrument must be grounded in accordance with local regulations by a qualified person.


SIGNIFICANCE OF INDICATORS

temperature indicator




Indicates the set temperature. After 200 hours of operation, FC will appear on the display to indicate that the filter needs to be cleaned. After cleaning the filter, press the reset button (located on the indoor unit behind the front panel) to reset the display (optional).




Operation indicator

The indicator lights up during operation. The indicator will flash in defrost mode.






Timer indicator

The indicator lights up during time setting.






Sleep timer indicator

The indicator lights up in sleep mode.




Compressor indicator

The indicator lights up when the compressor is on.





Super mode indicator

Lights up when super mode is in use.


The symbols for these models may vary, but they have identical functions.

AIR CONDITIONERS SERIES VM

NS SERIES AIR CONDITIONERS

Emergency button

ON/OFF (on/off)

Symbols for these models may vary, but they have identical functions. .

REMOTE CONTROL

The remote control transmits control signals to the indoor unit of the air conditioner.

On/off button ON/ OFF. The device will start working after power-up or will be stopped in the course of work after pressing this button.

Mode select buttonMODE . Press this button to select the operating mode.

Fan buttonFAN. Use to select fan speed in this order:

automatic - high - medium or low.

Room setting buttons temperatureroom Temperature Setting Buttons. Use to set the room temperature, as well as to set the timer and current time.

Fine tuning buttonSmart button.

Use the button to directly enter intelligent operation mode, regardless of whether the instrument is on or off.

Guide swing button airSwing button. Used to start the vertical air guide shift mode and adjust the up/down movement of the air guides.

Sleep timer buttonsleep button.

Used to set or cancel sleep mode.



Mode buttonI FEEL(option). Used to set or cancel the I FEEL mode (in this mode, the controller measures the room temperature and sends the information to the device for adjusting the settings).

clock buttonClock button. Used to set the current time.

Timer on/off buttontimer On/ Off button. Used to set or cancel the timer operation.

Super mode buttonSuper button. Use to start/stop operation of quick cooling/heating operation. (Quick cooling mode works with auto-set temperature of 18°C ​​+ high fan speed; Quick heat mode works with auto-set temperature of 32°C + auto fan speed).

Dimmer buttonDimmer button(option). Pressing this button will cancel the display of the indoor unit. To resume the display, press any button.

DISPLAY SYMBOLS




cooling indicator



Drying indicator



Mode indicator when only the fan is running



Heating mode indicator



Auto Fan Speed ​​Mode



High fan speed mode



Average fan speed



Low fan speed



Fine tuning function indicator



Sleep indicator



I FEEL mode indicator (the remote control measures the room temperature and transmits information to the device to adjust the desired parameter)



Super mode indicator



Signal transmission indicator



Timer setting display

Current time display





Set temperature display

Note: Each mode and corresponding function will be described in detail later on the instruction pages.

INSTALLING THE BATTERIES IN THE CONTROL PANEL


Storage and subtleties of using the remote control

The remote control can be stored in the wall holder.

Note: The remote control holder is an optional accessory.


How to use the remote control

OPERATING INSTRUCTIONS

Operating modes


SELECTING THE OPERATION MODE

Each time you press the MODE button, the operating mode of the instrument will change in the following sequence:

COOLING  DRY  FAN ONLY  HEATING

(cooling) - (dry) - (fan) - (heating)|

|____________________________________________

Heating mode is NOT available for air conditioners with only cooling mode .
FAN MODE SELECTION

Each time you press the FAN button, the fan speed will change as follows:

Auto  High  Medium  Low

(aut.) - (high) - (medium) - (low)

| ______________________________
If you select the “ FAN ONLY ”(fan only) only the parameters “ high "(high speed)," Medium ”(medium speed) and mode“ low "(low speed). In dry mode “ DRY ” fan speed is automatically set to “ AUTO ” and button “ FAN ” in this case becomes ineffective.



TEMPERATURE SETTING

Pressing this button once increases the temperature by 1°C.

Pressing this button once lowers the temperature by 1°C.

Range of available temperature settings

*Note: Heating mode is not available for cooling only air conditioners.
TURNING ON THE AIR CONDITIONER

Press the power on button while receiving a signal from the remote control to the indoor unit. The RUN indicator lights up.


Sometimes the device does not immediately respond to a mode change during operation. Pause for 3 minutes.

During the heating operation, the airflow will not start immediately. This will happen 2-5 minutes after the start of the mode and the rise in the temperature of the heat exchanger of the indoor unit of the air conditioner.

Please pause for 3 minutes before restarting the air conditioner.

ADJUSTING THE AIR FLOW DIRECTION

The vertical airflow is adjusted automatically to a certain angle, taking into account the selected air conditioner mode after the device is turned on.
Modes COOLING (cooling), DRY (dehumidification) - the direction of air flow will be horizontal.
Modes HEATING (heating), FAN ONLY (fan only) - the air flow will be directed downwards.
You can adjust the airflow as you wish by pressing the “SWING” button on the remote control.


* Heating mode is only available for air conditioners with this mode.



Control of the vertical direction of air flow (using the remote control)

Using the remote control, you can adjust different angles of air flow direction or a specific angle as you wish.

Multi-directional airflow

Pressing the “SWING” button once will select the mode of automatic movement of the air conditioner up and down.

Desired airflow direction

Pressing the “SWING” button again will allow you to set the guides in the direction you need.
Horizontal airflow direction (using hands)

Do not turn the vertical air guides by hand - this may cause a malfunction of the air conditioner. If this happens, first turn off the device and then disconnect it from the power supply. Then re-apply power to the instrument.

To prevent water condensation from escaping from the indoor unit, it is not recommended to set the vertical air flow direction knobs to the “down” position for a long time, especially in COOLING or DRY mode.
SMART SETUP MODE


Press the SMART button. The instrument enters SMART mode directly, whether it is on or off. In this mode, the temperature and fan speed will be automatically adjusted according to the actual room temperature.

Operating mode and temperature determined based on room temperature

Heat pump models


Room temperature

Working mode

Desired temperature

21°C or below

HEATING

22C

21C -23C

FAN ONLY

23C - 26C

DRY

The temperature will be reduced by 1.5°C after 3 minutes of operation of the device

Over 26С

COOLING

26C

Cooling only models



The SMART button will not work in SUPER mode.

Note: Temperature, airflow and direction are automatically adjusted in SMART mode. However, if you still want to adjust the room temperature with the selected SMART mode, then this is possible within (+ -2) degrees Celsius.
INSTRUMENT CAPABILITIES IN SMART MODE


Your feelings

Button

Adjustment Procedure

Uncomfortable due to incorrect airflow volume



The indoor unit fan will change its operation mode every time you press the FAN button (High,Medium,Low)

Uncomfortable due to incorrectly chosen direction of air flow



Pressing the button once will change the vertical direction of air movement. The next press will stop the air guides. See the section on adjusting airflow directions for details.

CLOCK SETTING BUTTON

TIMER MODE

Using the TIMER ON/OFF buttons allows you to set a comfortable temperature for your return home. You can also set the timer to turn off at night to enjoy your sleep.


HOW TO SET THE TIMER ON

The TIMER ON button can be used to program a timer of your choice to turn on the air conditioner at your desired time.

i) Press the TIMER ON button, the display will show “ON 12:00”. Use the or buttons to select the desired time to turn on the appliance.

Click the button TIMER ON 1 time to increase or decrease the time by 1 minute.

Click the button TIMER ON 1 time and hold it for ½ second to increase or decrease the time setting by 10 minutes.

Click the button TIMER ON for a longer time to increase or decrease the time by 1 hour.


Note: If the time is not set within 10 seconds after pressing the TIMER ON button, the controller will automatically exit the on timer mode.
ii) When the desired time appears on the display, press the TIMER ON button to confirm your selection.

  • You will hear a beep

  • The “ON” indicator stops flashing

  • The TIMER indicator on the indoor unit lights up
iii) 5 seconds after the timer is displayed, the controller displays the current time data instead of the timer settings.
HOW TO CANCEL THE ON TIMER

Press the TIMER ON button again. You will hear a beep and the mode indicator will disappear. The power-on timer mode will be cancelled.


Note: Similarly, you can set the timer to turn TIMER OFF. In this mode, the device will turn off automatically at the time you set.
SLEEP MODE

Sleeping mode SLEEP can be configured during the use of modes COOLING, HEATING, DRYING.

This function will allow you to create comfortable conditions for sleep.


Sleep mode

• The appliance will stop automatically after 8 hours of operation.


• The fan speed will automatically be set to low.
* The set temperature will increase by a maximum of 1°C if the appliance is operated in cooling mode for 1 hour. Then the temperature stabilizes.
• The set temperature will decrease by a maximum of 3°C if the appliance is continuously operated in heating mode for 3 hours. Then the temperature stabilizes.
* Note: In cooling mode, if the room temperature is 26°C or higher, the set temperature will not be changed.
Note: Heating mode will NOT be available for cooling only air conditioners.


SUPER MODE

 The SUPER mode is used to start or stop the fast cooling or fast heating mode.

Fast cooling mode operates at high fan speed, automatically changing the set temperature by 18°C. Fast heating mode uses automatic fan speed, automatically changing the set temperature to 32°C.
 SUPER mode can be set while the air conditioner is running or when the unit is receiving power.
 In SUPER mode, you can set the airflow direction or the timer. To exit the SUPER mode, press the SUPER,MODE,FAN,ON/OFF,SLEEP,TEMPERATURE SETTING button. The display will return to its original mode.
Note:

The SMART button will not be available in SUPER mode

The instrument will continue to operate in SUPER mode unless you exit this mode by pressing one of the buttons.

CARE AND MAINTENANCE


Front Panel Care

Air filter care

Turn off the power supply to the device.

Before turning off the power supply, be sure to turn off the instrument.


Clean the air filter every 100 hours of operation of the device. Perform cleaning as follows:

To remove the panel, grasp the "a" marks and remove the panel in the forward and upward direction.



Stop the appliance and remove the air filter.


  1. Open front panel.

  2. Gently press down on the filter handle at the front.
3. Hold the handle and slide the filter.

Wipe the front panel with a soft, dry cloth.

For heavy soiling, use water at room temperature (below 40°C)


Never use combustible mixtures (kerosene, polishing powder) to clean the device.



Clean the filter and reinstall it.

In case of heavy soiling, use a room temperature detergent solution. After cleaning, dry the filter thoroughly in the shade.



Never pour water on the air conditioner indoor unit. This may result in electric shock.



Replace the panel and secure it.

Hold the panel at points b and fix it downwards.


Close the front panel again.

Clean the filter every 2 weeks if the air conditioner is operated in extremely dirty conditions..

AIR CONDITIONERHISENSE

INSTRUCTIONS FOR

USE

AND INSTALLATION

AS-07HR4SVNNS

AS-09HR4SVNNS4

AS-12HR4SVNNS1

AS-24HR4SFJNS

AS-07HR4SVNVM

AS-09HR4SVNVM4

AS-12 HR4 SVNVM1

Thank you for purchasing the brand air conditionerHisense. Before installing the appliance and using it, please read these instructions carefully and save them.

CONTENT:

Preparing for Use………………………………………….........2

Presetting the remote control.............2

Remote control backlight function...............................................3

Auto Restart Preset .......................................3

Designation of the working parts of the air conditioner .........................................3

Precautionary measures................................................ ........................four

Meaning of indicators .................................................................. ............................5

Emergency button .................................................................. ....................6

Remote control............................................... ........7

Meaning of symbols on the display............................................................... ........eight

Installing Batteries in the Remote Control....................................................... .eight

Remote control storage and usage ..............................................................9

Operating instructions for the remote control ............................................... ...........9

Temperature setting ................................................................ ........................ten

Switching on the air conditioner .................................................. .....................ten

Adjusting the Airflow Direction...............................................................10

SMART mode ..........................................................................11

Instrument Capabilities in SMART Mode .............................................................. ..12

Clock setting button CLOCK .................................................................. ...............12

Timer Mode ................................................................ ........................................12

How to set the timer to turn on .............................................................. ........12

How to cancel the wake-up timer .............................................................. .........13

Sleeping mode................................................ ................................................13

Super mode .................................................. ............................................13

Instrument care and maintenance .............................................................. ......fourteen

Instrument protection .................................................................. .......................................fifteen

Characteristics of the protective device .......................................................... ...fifteen

Characteristics of the heating mode .............................................................. .............fifteen

Possible Problems and Solutions .............................................................. ........16

Air conditioner installation instructions ............................................... ..17

Selecting a location for installation............................................................... ......................17

Installing the indoor unit .......................................................... ....................eighteen

Installing the outdoor unit............................................................... ......................23

Vacuumization of the system .................................................. ...............................23

Notes................................................... ...............................................24

PREPARATION FOR USE

Before using the air conditioner, be sure to check and preset as follows.

Remote Control Preset

The remote control may not be factory preset.

If you find flashing indicators on the display even after powering up the remote control, then you need to select the mode for the remote control yourself.

 Pressing any of the buttons while the indicator is flashing will pre-configure the remote control for heating-drying mode.

 Pressing any of the buttons while the LED is blinking will preset the console for cooling mode only.

The absence of flashing indicators will mean that the control panel has a preliminary automatic setting for heating-drying mode.

Note:

If the air conditioner you purchased has only cooling mode, and the remote control is pre-configured for heating-drying mode, this does not matter.

But if you have purchased an air conditioner with heating-drying mode, and the remote control is preset for cooling mode, then the heating function will be lost. You will need to pre-configure the remote control for heating-drying mode.

Backlight function (optional)

Hold any of the buttons on the remote for about 2 seconds to turn on the backlight. The backlight turns off automatically after about 10 seconds.

Note: The backlight is an optional (additional) function.

Automatic restart preset

The air conditioner has an automatic restart function. You can set or cancel this function while the air conditioner is running.

• Hold down the emergency button (ON/OFF) for a few seconds. This function will be set after 2 beeps. If you hear 1 beep, this function will be cancelled.

DESIGNATION OF WORKING PARTS OF THE AIR CONDITIONER

(outdoor and indoor units)

AirIntake- holes for air intake

Frontpanel - Front Panel

Display panel– display panel

Emergencypanel– emergency control panel

Airoutlet- air outlets

Verticaladjustmentlover– regulators of the vertical direction of air

Horizontaladjustmentlover– horizontal air direction regulators

Airfilter– air filter

Remotecontrol- remote control

AirIntake- holes for air intake

Pipesandpowerconnection- connecting tubes and power cord

DrainHose- drainage hose

Note: Water condensate will flow out in COOLING mode or DRY dehumidification mode

Airoutlet- air outlets

Please note that the data in the description of the appearance of the device is based on the standard model. Accordingly, the forms may vary depending on the model you purchased.
PRECAUTIONARY MEASURES

The symbols in this manual have the following meanings:

Action prohibited.

Pay attention to such information.

Grounding is mandatory.

Warning: Improper handling may endanger health or result in serious injury.

Use the power according to the instructions on the device. Otherwise, there is a risk of serious damage or fire.

Protect the power switch and plug from dirt. Install the power plug correctly and firmly. Incorrect installation may result in electric shock or fire due to insufficient contact.

Do not use the power switch or pull on the power plug to turn off the appliance while it is in operation. This may cause a fire due to sparking.

Do not twist, pull or put pressure on the power cord, otherwise it may be damaged. A damaged power cord may cause a fire or electric shock.

Do not insert sticks or similar objects into the appliance. It may cause injury because the fan in the appliance rotates at high speed.

Prolonged and directed cooling is dangerous to your health. Make sure that cold air is distributed throughout the room.

First, turn off the device via the control panel and only then turn off the power to the device in case of malfunctions.

Do not repair the device yourself. Improper repairs may result in electric shock, etc.

Make sure that the air flow from the air conditioner does not reach the gas burners and stove.

Do not touch the air conditioner control buttons with wet hands.

Do not place foreign objects on the outside of the air conditioner.

Grounding is the responsibility of the user of the instrument. The instrument must be grounded in accordance with local regulations by a qualified person.

SIGNIFICANCE OF INDICATORS

temperature indicator

Indicates the set temperature. After 200 hours of operation, FC will appear on the display to indicate that the filter needs to be cleaned. After cleaning the filter, press the reset button (located on the indoor unit behind the front panel) to reset the display (optional).

Operation indicator

The indicator lights up during operation. The indicator will flash in defrost mode.

Timer indicator

The indicator lights up during time setting.

Sleep timer indicator

The indicator lights up in sleep mode.

Compressor indicator

The indicator lights up when the compressor is on.

Super mode indicator

Lights up when super mode is in use.

The symbols for these models may vary, but they have identical functions.

SERIES AIR CONDITIONERSVM

SERIES AIR CONDITIONERSNS

Emergency button

ON/ OFF(On Off)

Symbols for these models may vary, but they have identical functions. .

REMOTE CONTROL

The remote control transmits control signals to the indoor unit of the air conditioner.

On/off button ON/ OFF. The device will start working after power-up or will be stopped in the course of work after pressing this button.

Mode select buttonMODE . Press this button to select the operating mode.

Fan buttonFAN. Use to select fan speed in this order:

automatic - high - medium or low.

Room setting buttons temperatureroomTemperatureSettingButtons. Use to set the room temperature, as well as to set the timer and current time.

Fine tuning buttonSmartbutton.

Use the button to directly enter intelligent operation mode, regardless of whether the instrument is on or off.

Guide swing button airSwingbutton. Used to start the vertical air guide shift mode and adjust the up/down movement of the air guides.

Sleep timer buttonsleepbutton.

Used to set or cancel sleep mode.

Mode buttonIFEEL(option). Used to set or cancel the I FEEL mode (in this mode, the controller measures the room temperature and sends the information to the device for adjusting the settings).

clock buttonClockbutton. Used to set the current time.

Timer on/off buttontimerOn/ Offbutton. Used to set or cancel the timer operation.

Super mode buttonSuperbutton. Use to start/stop operation of quick cooling/heating operation. (Quick cooling mode works with auto-set temperature of 18°C ​​+ high fan speed; Quick heat mode works with auto-set temperature of 32°C + auto fan speed).

Dimmer buttonDimmerbutton(option). Pressing this button will cancel the display of the indoor unit. To resume the display, press any button.

The Chinese industrial group Hisense is the world's largest manufacturer of household and industrial appliances. The company is engaged in the production of ducted air conditioners, premium models, household Hisense multi-split systems. In the Russian market, the products of this brand appeared in the early 2000s and won the trust of customers with their quality, assortment and affordable prices.

NEO Premium Classic A series

The flagship of the company can be considered the Neo Premium classic A line of air conditioners. This is the second generation of models without an inverter, which is distinguished by good technical and operational qualities. To optimize costs, a system was developed to reduce electricity consumption, almost all functions are fully automated.

The type of indoor unit is classic, with rounded edges. The digital LED indicator is located behind a translucent plastic, which does not interfere with reading the readings. The Neo Premium classic A series differs from the standard budget models in the soundproofing of the outdoor unit - it works much quieter than conventional air conditioners.

Features of Hisense Neo Classic A:

  • fully automatic blinds with the possibility of remote adjustment of their position;
  • Toshiba compressor, which provides the proper rate of compression of the refrigerant, emits a minimum of noise during operation;
  • a complete set of filter elements of the neo model.

In fact, the classic refers to the type of budget air conditioners, but at the same time, the multi-split system has good performance indicators, ease of maintenance and intuitive settings. In the photo, the design of the indoor unit is close to the standard one, which makes it possible to fit it into any interior of a living room.

The user must clean the installed air filters himself. To do this, you need to remove the front panel of the indoor unit, after de-energizing the Hisense wall-mounted air conditioner.

Smart DC Inverter Series

For greater energy savings and improved performance, the company has developed inverter air conditioner Hisense Smart DC Inverter. Models have an expanded range of power parameters - from 7K to 24K. Also, systems for intelligent adjustment of current indicators are used.

The design of the Hisense indoor unit split system remained recognizable, the design of the components and their functionality have changed. The buyer can choose only one color - white. Japanese outdoor unit compressor - Toshiba. Unlike ducted air conditioners, models can serve only one room.

Advantages of Hisense Smart DC Inverter multi split system:

  • the optimal step for the cooling performance of the Hisense air conditioner is 0.5 kW;
  • Hisense inverter split systems have improved air filtration;
  • the "Smart" function will allow you to set the operating mode at the user's location;
  • changing the position of the blinds in the horizontal and vertical plane.

Another advantage is the price - Hisense air conditioners in this series cost from 21,000 rubles. When choosing, it is important to pay attention to the first two characters - vrv or vrf indicate the absence inverter system. Intelligent and energy-saving climate control systems are designated by the letters AS.

To set up a Hisense multi-split system, you need to read the recommendations from the manufacturer. There should be no obstacles in the way of the air flow, the angle of rotation of the blinds is additionally taken into account.

Overview of additional series

To increase the range, the manufacturer has developed several collections that differ from those described above only in design and size. So, you can purchase a Hisense wall-mounted air conditioner with a minimum thickness of the indoor unit, which is important for small rooms. A ducted air conditioner or its more powerful counterparts, Hisense column air conditioners, do not have such a variety.

The difference between the models is appearance, absence or presence additional features. The choice of such systems is relevant if the design of the Hisense AS air conditioner is not suitable for the interior of the room. To do this, the company has developed several series that differ not only in shape, but also in color solutions.

The most interesting models:

  • Hisense Premium FUTURE Design DC Inverter wall mounted air conditioner. It features a rounded shape of the indoor unit body and elegant colored inserts along its edges. The Mirage display is not highlighted when turned off.
  • BLACK Star DC Inverter. The form is exactly the same Smart series DC except for the body color which is black. Functions and specifications remained the same.
  • Premium Slim Design Super DC Inverter. The thickness of the case is 11.3 cm. At the same time, the maximum set of options has been preserved. The color of the block is cream. It is also possible to work with significant voltage drops. The minimum indicator is 175 V.

The table shows the main characteristics of inverter and simple models Hysens.

Instructions for the control panel and Hisense air conditioners

To control the operation of the air conditioner, the manufacturer has developed a convenient remote control. The location of the buttons on it allows you to quickly change the current mode of the climate system, the data on the liquid crystal display shows the parameter values. The only downside is the small screen size.



For ease of operation, the user can select the following functions:

  • Cooling mode with set temperature. Some models provide control of a certain zone in the room.
  • Ability to choose how to adjust the air conditioner - manually or automatic mode. In the latter case, the system will change the parameters itself, depending on the air temperature in the street and in the room.
  • Detailed instructions on how to adjust the multi-split system - setting for heat, ventilation or cooling.

It should be remembered that to reset the settings, it is not enough just to turn off and then turn on the remote control - they are saved automatically.

When servicing an air conditioner, it is important to know what type of refrigerant must be added to the system. Most models are compatible with R410A freon. It must not be mixed with other refrigerants as it may cause damage.

Hisense Air Conditioner Error Codes

When properly installed and maintained, the air conditioning system is less likely to fail. It will work for both cooling and heating. The main advantage of air conditioners of this brand is their reliability. But, like any other equipment, climate equipment can fail, malfunctions will appear.

Below you can find instructions for maintenance and self-elimination small defects.

It is forbidden to carry out repairs in any form in the presence of the following faults:

  • a sharp drop in performance;
  • appearance excessively a large number condensation on the indoor unit;
  • noise increase;
  • fan failure;
  • loss of tightness of pipelines.

Previously, you can familiarize yourself with the error codes for the indoor unit. If faults occur, they will appear on the display or remote control.

To display error codes on the display, press the “Sleep” button 10 times. This feature is not available on older models.


4D AUTO Air
Vertical and horizontal automatic air flow distribution, the possibility of full-volume air distribution throughout the room with no "stagnant" zones, or precise redirection to the required point


MIRAGE display
Thanks to the MIRAGE display function, when the air conditioner is off, the display is not visible on the front panel. This creates a more modern and stylish look to the front of the unit.


SMART mode
Automatic mode selection, based on the need to maintain the target temperature in the room within 22-26 ° C, with minimal power consumption


Function I FEEL
The temperature sensor, located directly in the control panel, and the ability to switch the logic of the air conditioner to measure the temperature with this sensor, provide an accurate temperature directly at the person’s place of residence


energy efficiency
The energy efficiency of the air conditioner meets or exceeds the Class A range of the Russian classification system


ULTRA Hi Density Filter
Dust filter for general cleaning, produced according to new technology, has a much smaller cross section of cells compared to standard ones, which makes air purification better


Additional filters
Comprehensive air purification: all air conditioners are equipped with additional filters to purify and improve air quality


Low noise
Specially designed air duct and air distribution system combined with the Quiet function ensures low noise levels


Protective cover for valves outdoor unit
A special algorithm for the operation of the air conditioner after turning it off leaves the fan of the indoor unit in working condition for some time. This allows the heat exchanger to dry out after operation.


Self cleaning function
Hisense split systems are supplied with a protective overlay for the valves of the outdoor unit. This prevents precipitation from affecting important compounds.

4D AUTO Air

HISENSE's new room air distribution technology provides the user with maximum comfort.

Automatic horizontal and vertical blinds allow you to choose any of 4 comfortable in this moment modes:
. Simultaneous automatic operation of these blinds allows you to cool the room most evenly, creating the effect of constant air movement, without the appearance of a draft inside the room.
. The fixed position of the horizontal louvers with automatic operation of the vertical louvers allows directing the air flow to the right and left in a given horizontal plane.
. The fixed position of the vertical louvers with automatic operation of the horizontal louvers allows you to direct the air flow up and down in a given vertical plane.
. The constant position of the horizontal and vertical louvres enables spot cooling.

MIRAGE display

The front panel of all wall-mounted split-systems is made of translucent plastic, thanks to which the display developed by HISENSE - MIRAGE is implemented, which remains completely invisible if the air conditioner is turned off.

Smart mode - Smart mode

A convenient mode for cases of a sharp drop in temperature outside during the day, or for users who do not want to think about choosing the operating mode of the air conditioner. It is enough to select the desired room temperature and SMART mode, and a special free logic algorithm will determine the operating mode of the air conditioner and the best fan mode settings.

Function I FEEL

A temperature sensor is installed in the HISENSE remote control, thanks to which it is possible to more accurately maintain the temperature in the room, directly at the location of people.

energy efficiency

The energy efficiency of equipment is becoming more and more important every year. If earlier high values ​​of this indicator indicated the quality of equipment and a high technological level, now, with the increase in electricity tariffs, energy efficiency is becoming an important economic factor when making a purchase decision, as it directly affects the additional costs associated with the operation of the air conditioner. At the moment in different countries There are several classifications of energy efficiency of separate type air conditioning systems (split systems).

Russian classification of energy efficiency of air conditioners

The classification currently used in Russia is similar to the European one that was used before January 1, 2013. The Russian classification system is quite simple and understandable - it takes into account the direct ratio of the generated cooling or heating power to the electricity consumed when operating in the nominal mode. For cooling and heating modes, the values ​​of this coefficient are different. To determine the energy efficiency class in cooling mode, it is necessary to take the rated cooling capacity, divide by the nominal value of energy consumption in cooling mode, compare the resulting value with the table and understand which class the air conditioner belongs to. This indicator is called EER - Energy Efficiency Ratio - The coefficient of energy efficiency of the system in cooling mode. A similar calculation is made for the heating mode. The coefficient showing efficiency in heating mode is called COP - Coefficient of Performance - performance coefficient in heating mode. All equipment, in accordance with the rules, must be marked with a clear color sticker indicating the class.

European Union Air Conditioner Energy Efficiency Classification

In Europe, since January 1, 2013, a complex system for determining the energy efficiency of air conditioners has been adopted. Her methodology is based on the fact that the air conditioner does not work all the time in nominal mode, that is, with a full load. Most of the time, the air conditioner operates at partial load, which means that the ratio of cold (or heat) produced does not correspond to the nominal values. This technique has the greatest practical meaning for air conditioners using inverter control technology, that is, air conditioners that can smoothly change their power, adjusting to the required partial load. It involves measuring the ratio of the produced cold (heat) to the corresponding energy consumption at 4 different loads. After that, weight coefficients are applied to the obtained values, showing the frequency of operation of the air conditioner in this mode, then the obtained values ​​are summarized. Since air temperatures differ throughout the year in different climatic zones, different weight coefficients were introduced for different territories.

The European Union was divided into 3 climatic zones, with similar temperature indicators throughout the year.

The new method shows the seasonal energy efficiency of an air conditioner.

For cooling mode, this is the SEER - Seasonal Energy Efficiency Ratio - seasonal coefficient of energy efficiency of the system in cooling mode. For the heating mode, this is the SCOP indicator - Seasonal Coefficient of Performance - the seasonal coefficient of performance of the system in heating mode.

At the same time, it must be understood that the technique does not directly show the ratio of consumed electricity and output power, but serves to correlate various air conditioners with each other. In addition, measurements of these indicators must be carried out by certified laboratories, since they cannot be directly verified by consumers.

Low Noise - Quiet Mode

The design of the indoor unit has been optimized, including:
. a new design of the fan impeller of increased diameter with a new shape of the blades,
. low noise motors
. a specially designed aerodynamic solution for the entire air channel, starting from the air intake grille, continuing it through the heat exchanger of an improved design, the shape of the air nozzle and the special shape of the louvre.

All this made it possible to reduce the noise level of the indoor unit to extremely low values, which for premium models are 22 dB (A) in low noise mode.

ULTRA Hi Density Filter

The ULTRA Hi Density filter is a new generation high purity filter. Compared to a conventional dust filter, the high-purity filter removes more than 90% of dust and other particles from indoor air. The filter is simply cleaned of contaminants under running water.

Additional filters

LTC filter
LTC filter or formaldehyde filter removes harmful organic compounds from the room.

carbon filter
Since charcoal is an excellent absorbent, this type of filter effectively absorbs odors and many types of chemicals.

Photocatalytic filter
Filters of this type are able to effectively oxidize and destroy molecules of chemical compounds, odors, as well as viruses, bacteria, fungal spores and other pollutants of organic origin. The filter can be quickly restored by keeping it in the sun for 6-8 hours after 3-4 months of operation.

Silver Ion filter
The air flow passing through this filter is cleaned with silver ions, which are able to prevent the appearance of germs and bacteria. In addition, the remaining silver ions are carried by the air flow into the room, retain fine dust particles, thereby continuing to disinfect the air.

HEPA filter
The HEPA filter is a super high-purity filter, as it effectively traps the smallest elements of dust, allergens, pollen and a number of others.

Negative Ion Filter
The Negative Ion filter produces negatively charged ions, which, in addition to having a positive effect on the body, are actively involved in the process of air purification. They transfer the charge to the dust particles, which begin to attract each other and form larger particles, increasing the efficiency of air purification.

Protective cover for outdoor unit valves

Hisense split systems are supplied with a protective overlay for the valves of the outdoor unit. This prevents the impact of atmospheric precipitation on important connections and increases the reliability of operation.

Self cleaning function

A special algorithm for the operation of the air conditioner after turning it off leaves the fan of the indoor unit in working condition for some time. This allows you to dry the heat exchanger from the condensate that forms during operation.

State-of-the-art self-adaptive BLDC control technology for compressor motors

State-of-the-art self-adapting BLDC compressor motor control technology helps air conditioners run quieter and more efficiently.

Combination of BLDC motor (brushless motor direct current) with new control algorithms make it possible to achieve:
. low noise
. high performance
. a higher level of stability and service life

Intelligent PFC control technology

PFC control technology can maintain the required voltage when it needs to be compensated in case of low mains voltage.

The air conditioner control system independently turns this function on or off.

The PFC works according to the current supply voltage conditions so that the operation continues to be as efficient as possible when the voltage is not stable.

The operating voltage range becomes increased, it may differ from the nominal voltage by 20%.

Starting and torque compensation technology at low frequencies

According to the compressor load curve, HISENSE developed low frequency torque compensation technology.

This technology improves the stability of the compressor at low frequency, reduces the vibration of the compressor, and extends the operation range at low frequency to 10Hz, which expands the compressor's power range.

Nonlinear Magnetic Control Technology

The unique non-linear magnetic control technology developed by HISENSE can operate at high frequency under high load conditions, in a wider frequency range to ensure greater cooling/heating capacity.

FULL 3-DC INVERTER technology (Super DC Inverter HISENSE)

HISENSE Premium DC Inverter air conditioning systems use FULL 3-DC INVERTER technology.

It includes not only the use of a DC INVERTER compressor for maximum efficiency, but also all components produced using DC INVERTER technology.

First of all, these are the fan motors of the external and internal blocks. Full inverter control of all elements of the air conditioner allows not only to create the most quiet and comfortable air conditioner, but also to make it as energy efficient as possible, which is confirmed by the European seasonal energy efficiency class A ++.

Consumption in standby mode 1W - 1W Standby

Thanks to the improved design of the power supply, it has become possible to reduce the power consumption in standby mode to a uniquely low value - only 1 W. This means that when the air conditioner is turned off, it actually does not consume electricity to maintain itself in standby mode and to power the memory block where last settings.

Accurate room temperature control

HISENSE air conditioners of the Super DC Inverter and DC Inverter class give the user a new level of comfort.

The combination of all inverter power control technologies, the I FEEL function and HISENSE's special developments in the field of inverter control made it possible to make temperature maintenance even more accurate, even compared to conventional Inverter systems. This ensures that the temperature is kept as close as possible to the value set on the remote control.

Cold Plasma Ion Generator – Plasma air purification

Plasma air purification kills viruses and neutralizes toxic substances, prevents the spread of infectious diseases, removes dust and unpleasant odors, and creates the effect of fresh forest air in the room.

Sleep mode - sleep mode

HISENSE brings innovation to the now familiar Sleep Mode. The user is offered a choice of 4 different modes, each of which is characterized by different preset parameters.

We are talking about various automatic temperature maintenance settings that allow you to choose the most comfortable mode for different ages, for each individual person.

Intelligent defrosting system of the external unit Smart Defrost

In winter, during heating operation, ice forms on the heat exchanger of the outdoor unit.

To continue the operation of the system, it is necessary to carry out the defrosting procedure to normalize further operation.

As a standard, this issue is solved by turning on the defrosting mode by timer, which leads to a stop in the normal operation of the air conditioner even in cases where ice has not yet formed.

The intelligent Smart Defrost algorithm developed by HISENSE operates only when needed, which reduces energy consumption by eliminating unnecessary processes defrosting. This brings additional comfort in heating mode and reduces the defrost time.

Indoor unit fan

New development of HISENSE - asymmetric tangential fan. During its development, the latest achievements were applied not only in theoretical, but also in experimental aerodynamics, which made it possible to create a fan that is truly outstanding in its characteristics. The increased performance of the fan made it possible to reduce the speed of its rotation, which led to a decrease in noise from the engine, which began to rotate at a slower speed. At the same time, the air flow became more powerful and quieter.

Outdoor unit fan

The design efficiency of the outdoor unit fan is just as important as that of the indoor unit fan. Although the consumer does not notice his work, but it is the design of the fan of the external unit that is largely responsible for the energy efficiency of the air conditioning system as a whole. HISENSE has carried out special developments in this area. This made it possible to create a fan of a new, maximally aerodynamically efficient design.

Protection of components in the indoor unit

Protective metal box for electrical components in the indoor unit

International safety standard. Each air conditioner undergoes 52 validation tests, in accordance with US regulations, including the IEC test, to ensure the highest safety standards.

Fireproof plastic and connector

For the Super DC series and the Premium Classic A HISENSE series, flame retardant, safe plastic materials are used. In the event of a fire, these plastic materials will prevent the spread of flames.

Aluminum finning of complex profile heat exchangers

The aluminum plates used in the production of heat exchangers for HISENSE air conditioners are very different from the classic "smooth" version. They have a complex shape obtained by pressing, as well as additional notches of a special shape. This makes the heat exchange process much more efficient than the traditional one. Heat transfer occurs more quickly and evenly.

Additional coating of the GOLDEN FIN heat exchanger

This technology is applied to the aluminum plates of outdoor units.

The outer layer of aluminum tends to oxidize slowly, which changes the heat transfer efficiency over time, and also leads to faster surface contamination, which reduces heat transfer.

The GOLDEN FIN protective coating is a nanolayer of a special yellow plasticizer (hence its name), which gives the heat exchanger several additional properties at once.

It blocks the oxidation process, preserving the aluminum surface. The surface becomes much more “slippery”, so surface contamination is much slower.

The “slippery” surface increases the efficiency of work in the cold season in the heating mode, as it accelerates the removal of condensate and the efficiency of the “defrost” mode.

This coating makes the heat exchanger unit of the outdoor unit as resistant to aggressive environments as possible and is used, for example, for equipment supplied to coastal regions.

Use of copper tubes with internal fins

The heat exchangers for Hisense air conditioners are manufactured using specially designed copper tubes. Unlike standard tubes with a smooth inner surface, these tubes are internally finned.

This allows you to increase the heat exchange area and create an additional effect of turbulence inside the tubes, which in total significantly increases the efficiency of work.

This allows the use of smaller pipes, which reduces the amount of refrigerant in the air conditioner, and also allows the units to be made more compact without sacrificing energy efficiency.