Review of Galanz air conditioners: error codes, comparison of wall models. How to set up a universal remote control for the air conditioner Operating instructions for the galanz air conditioner

Instructions on the following model:

GIOWI09RK16
GIOW07RG24

Galanz air conditioner GIOWI09RK1

Table of contents
Disposal
Name of each part
Preparation before starting work
Selection of operating modes

Useful Tips
Cleaning your air conditioner
If you think there is a problem
When will not be used for a long time (At the end of the season of use)
Installation site and electrical work
Precautionary measures

Disposal
When creating this model, materials were used that can be sent for recycling. For this reason, it is necessary to check with territorial bodies authorities, how exactly to dispose of specifically in your area.

Name of each part
Outdoor unit

During operation, outside air is drawn in at the rear and sides (1). After contact with the heat exchanger, it is discharged on the front side (2).

Indoor unit

Air enters inward on the upper side of the housing (1). In area 2 there are indicators and a sensor that receives commands from his remote control. 3 - the area where the air comes out. When the air conditioner is off, it is closed.

Preparation before use
Connect the appliance to the mains using a socket of a sufficient rating. The grounding must be correct.
Remember to install batteries in the remote control. Attention! Do not use batteries of different charge levels and types. Do not use rechargeable batteries.

Choice of operating modes
Using the remote control, you can turn on and set the required operating mode. These can be five basic modes. In automatic mode, the device will independently maintain the temperature in a given range by connecting either cooling or heating. If you only need to cool or warm, then a separate mode is suitable - heating or cooling. In the dehumidification mode, the air conditioner will remove water dissolved in the air almost without cooling it. Therefore, the desired temperature cannot be set in this mode. In the "fan" mode, the device simply organizes air recirculation throughout the room.

Add. modes and settings
This model is useful in that, when working, it is able to supply street air to the room, thereby eliminating the need to ventilate the room.
The automatic restart system will automatically turn on your air conditioner to operate in the same mode as before the power failure.
Thanks to the timer, you can program the on / off of the device independently of people. Moreover, it is possible to both turn on and off at the desired time. This will prepare the apartment for coming home from work or waking up in the morning.
Night mode makes the operation of the device quieter, which allows you to sleep even when the air conditioner is running.
Air ionization makes the air in your home cleaner from microorganisms dust.

Useful Tips
If you're struggling with the heat, don't overdo it - the cold is bad for your health and your energy costs will rise.
Keep an eye on the room where the air conditioner is operating - air will escape through the open windows and doors, which will impede the operation of the device.
Controlling the direction of the horizontal baffle is also important. Warm air must be directed to the floor, cold - parallel to it.
A clean air filter is also important as it can put additional strain on the fan.

Cleaning the air conditioner
All actions should be carried out with dry hands, until you disconnect the device from the mains.
Use only reliable support. It is not recommended to use hot water, abrasives and gasoline, because you just spoil appearance your product.
Dry all parts of this air conditioner in the shade.

If you think there is a problem
It should not be considered a malfunction when the air conditioner resumes its operation by itself after the reappearance of energy in the network - this may be an automatic restart operation after a shutdown.
If the appliance stops heating / cooling completely, this may be due to a refrigerant leak. You need to contact the service.
Failure to start within 3 minutes after shutdown is normal operation of frequent start protection.
While heating your home, the unit will stop periodically, which is very important for defrosting the outdoor unit. In addition, be patient, turning on this mode - in order not to supply cold air, the device will not start the indoor unit immediately.
During air dehumidification, the device should not work continuously - since its main task is to remove moisture from the air without cooling it, the work will periodically stop.
Cold air (which comes out of the indoor unit when cooling and outside when heating the dwelling) will cause fog to appear in the area of ​​contact with ordinary air - this is the norm.
Please remember that during any thermal operation there will be cold components in the air conditioner, on which condensation will constantly appear. Therefore, water may sometimes leak from the outdoor unit.
If there is a problem with the remote control, first check if any button has been pressed. The batteries must be correctly installed, in good condition, charged.
If you cannot cool the room properly, check that you have selected the correct operating mode. Standard requirements must also be met: close windows, blinds (direct sunlight will heat the room). Hot weather and a heater will interfere with cooling the air.
If your air conditioner emits an unpleasant odor during operation, then it's time to check its internal cavity and filters. In addition, odors can be sucked in from the outside (from a wall or carpet).
Cracking sounds are not a sign of problems - plastic will make similar sounds as it expands when heated.
Refrigerant or condensate will make a bubbling sound as it moves through the piping system.

When you plan to stop using the conditioner for a while
Wash the outer parts, dry. Dry the indoor unit with heating mode for 3 hours. Turn off your air conditioner, unplug it from the power outlet, and remove the batteries from the remote control.
Before starting to reuse, check the air inlet / outlet for both units. With the air conditioner plugged in, put the batteries in your remote control.

Place for installation
It is not recommended to place the air conditioner in places where it will interfere with neighbors with its noise and drops of condensation. Also, do not place it near possible sources of flammable gases. Cannot be installed in places where there is hydrogen sulphide, a humid salty climate, an abundance of engine oil.

Precautionary measures
Due to the power of the appliance, it must be plugged directly into an outlet with the correct wattage. It is unacceptable to connect it to an extension cord or a low-power outlet. You cannot use it without grounding.
It is forbidden to independently repair, modify, change both the air conditioner itself and the power cable.
Do not place heavy, hot objects on either the blocks or the power cord.
Disconnect the device from the remote control before removing the plug from the socket.
Avoid prolonged exposure to cold air on people, animals, plants.
Do not insert anything into the openings of the air conditioner while it is running, which may cause injury.
If you detect a smell of burning, knocking, strange sounds stop the appliance, disconnect it from the mains and contact the repair specialist.
If your appliance stops heating / cooling - check if this is caused by a refrigerant leak.

Galanz air conditioner GIOW07RG24

Disposal
Since this product has been created using high-tech solutions and materials, it must not be disposed of as normal waste. In order to protect the environment, it is recommended to contact authorized companies.
Name of each part

Name of each part

External block.

1 - Back-side surface - air intake.
2 - Fan inside the outdoor unit.
3 - Air outlet from the outdoor unit.
Make sure that the air inlet and outlet areas are not obstructed by foreign objects.
Please be aware of this component that the noise generated during operation may disturb other occupants. Make sure that there is nothing to obstruct the air flow at the installation site. Due to the fact that the case of the outdoor unit is made of corrosion-resistant steel, it will serve you for many years.

Indoor unit.

1 - Air intake to the indoor unit.
2 - Indicator zone, window for receiving commands from the remote control.
3 - Air outlet from the indoor unit (closed when idle).
Its body is made of plastic, there are air intake and exhaust zones. It is important to ensure that they are not obstructed by foreign objects. On the front panel there is a window for receiving signals from the remote control, which must be at least one meter from the fluorescent lamps.

Remote controller remote control - is necessary for the full control of all actions that the air conditioner can perform.

1 - Button for turning on the timer.
2 - Display backlight in the dark.
3 - Turn on sleep mode.
4 - Buttons for setting the temperature - add and decrease.
5 - Power of the fan.
6, 7 - control of additional modes.
8 - selection of the angle of inclination of the horizontal partition.
9 - Selecting the operating mode.
10 - Connecting turbo mode.
11 - Switching the ionizer on / off.
12 - Switching on / off the operation of the air conditioner.
13 - Air freshening.
14 - Plasma filter connection.

Preparation before starting work

Installation is carried out by certified specialists. Before use, insert the plug into an outlet that is suitable for this device... The ground must be connected. Install batteries in the remote control. Please note that the batteries must be of the same type, new. Make sure there are no obstacles to air movement around the outdoor and indoor units. Turn on the device by pressing the ON | OFF button.

Selection of operating modes
The following operating modes are available for this air conditioner:
Auto;
Cooling;
The heating;
Dehumidification of air;
Fan.
The choice of the desired temperature is made by pressing the "up-down" buttons on the remote control.
In Auto mode the room temperature is maintained at a given level. When the temperature drops, heating is automatically turned on, and when the value you set is exceeded, cooling is turned on.
Cooling mode more convenient in the hot season. The air conditioner will keep the temperature not higher than the one you specified. At the same time, air will be dehumidified at the same time.
Dehumidification mode - the device will work to dehumidify the air, but at the same time minimally affecting the temperature. Install in this mode the desired value for the temperature is not possible.
Fan mode provides air circulation in the room.
Heating mode suitable for heating your home.

additional information... Due to the fact that the surface of the heat exchanger is characterized by increased wettability, moisture drains and leaves faster working area... This reduces energy costs. In addition, the heat exchanger tubes are designed to optimize heat transfer, which also contributes to lower energy consumption.
There is a cold air protection function. When space heating is started, the fan only starts running when the heat exchanger has reached a sufficient level.
The autostart function turns on and puts the air conditioner in the same mode in which it was working before the emergency power outage.
Additional modes and settings
Turbo mode allows you to increase the fan speed at will, which improves the efficiency when cooling or heating the air.
In the cold season, the heat exchanger warming and defrosting function will protect your outdoor unit from icing and damage.
To reduce the load on your wiring, a soft start system is provided.
Timer function - with its help you can specify the start time (start timer) and the shutdown time of the air conditioner. Which automates and simplifies the use of the device.
There is also a self-diagnostic function that will allow you to determine the condition of the air conditioner and possible problems without calling a specialist.
When using the air conditioner, you can connect an additional silent fan mode to reduce discomfort and power consumption.

Cleaning your air conditioner
Unplug the appliance to clean it. Choose a stable support for yourself.
Do not use gasoline, thinner, water hotter than 50 degrees Celsius, abrasive detergents for surface treatment. This can ruin the appearance of the plastic.

If you think there is a problem
The air conditioner does not work. Check if the plug is plugged into a power outlet.
I cannot turn on the device for 3 minutes after turning it off. This is normal and is intended to prevent frequent starts.
When heating starts, the indoor unit does not turn on for several minutes. This is normal - until the heat exchanger temperature reaches the desired value, the fan will not start.
In heating mode, the indoor unit turns off periodically. This is required to defrost the outdoor unit. In this mode, the outdoor unit is overcooled, so water freezes on it. To prevent damage to the device, it must be regularly freed from ice.
When operating in space heating mode, white smoke is emitted from the outdoor unit. In this mode, the outdoor unit delivers cold air to the outside. As a result, a fog begins to form around it, which looks like smoke.
After a power outage, the air conditioner turned on on its own, although no one was using the remote control. If, before the power outage in the network, the air conditioner worked in one of the modes set from the remote control, then after the power appears in the network, it will automatically continue to work in the same mode.
Water flows from the outdoor unit during space heating operation. This is normal as the heat exchanger of the outdoor unit cools down until condensation and ice appear on it.
The remote control does not work or the display is blank. It is necessary to check whether there are batteries, whether they are installed correctly and, if necessary, replace them with new ones.
There is no heating or cooling of the room. Check if the operating mode is set correctly. Are there any obstacles to air movement? Are there open doors and windows in this room? There may be a decrease in work efficiency if there are too many people in the room, it is very hot outside, and a heating device is used in the room.
After turning on the heating mode, the device does not turn on immediately. This is normal, the unit must warm up to the correct level before turning on the indoor unit.
There is a foreign smell in the air flow coming out of the air conditioner. First of all, it is necessary to check the presence of mold, then the smell may be from objects adjacent to the indoor unit (carpet or wallpaper).
Cracking sounds are heard during operation. This may be normal, as the plastic may expand as it heats up, causing it to crackle.
Gurgling sounds are heard during operation or when the device is turned off. During operation, the movement of condensate or refrigerant normally produces similar sounds. When the air conditioner is already off, water flowing through the hose may cause gurgling. Also, check if the exhaust fan is running, air will be sucked into the room through the condensate hose, causing a gurgling sound.

At the end of the season of use
1. Run the air conditioner on heating for about three hours to dry the indoor unit. This will protect against mold growth.
2. Switch off the device using the remote control.
3. Disconnect the plug from the power supply.
4. Remove the batteries from the remote control.

To turn on after a long period of inactivity.
1. Check if there are any obstructions to the air movement of both units (indoor and outdoor).
2. Check the ground connection.
3. Connect the plug to the power supply.
4. Install batteries in the remote control and use the device.

Installation site and electrical work
Please note that the outdoor unit will make noise, which may disturb people in the neighborhood.
Do not install the air conditioner in places where oil splashes may occur, in salty humid climates, in places with high-frequency electromagnetic equipment, or where there is no normal air outflow from the outdoor unit.
Installation must be carried out by specialists with special training.

Precautionary measures
Do not plug the plug into an extension cord or carry it around as this could cause a fire.
Do not disconnect the plug from the mains while the air conditioner is running. Disconnect it with the remote control first.
Do not move, repair or modify the air conditioner yourself. This must be done by certified employees.
Do not stand in the path of cold air from the indoor unit as it may cause illness.
Do not insert fingers or foreign objects into any openings in the air conditioner cabinet. This is fraught with injury.
If oddities appear in the operation of the air conditioner (smell of burning, unusual noise), then it is necessary to call the service staff.
Remember, if the unit does not cool or heat, then this may be due to a refrigerant leak. In this case, it is recommended to call a repair specialist to inspect and diagnose the device.
If you are not going to use the device for some time, disconnect it from the power supply.
Unplug this apparatus during lightning storms.

The instruction of the air conditioner control panel is divided into chapters, which describe in detail the functions and rules of use.

All air conditioner control panels are divided into infrared and wired. The latter type is used for industrial and semi-industrial plants... They transmit signals through thin special wires. One wired remote control controls 3 to 8 air conditioners. How to set up the air conditioner remote control is described in detail in the instructions.

Infrared remotes work optimally at a distance of up to 4 meters.

At a distance of 4 to 8 meters, bright illumination can disrupt the path of the infrared beam.

The instruction of the air conditioner control panel begins with a schematic representation of the device with the designation of its parts and buttons.

Main functions

The description of the air conditioner remote control reads: in order to enter the menu of basic functions, it is necessary to drown the MODE button. The display shows the modes:

  • HEAT- the air heats up to 30 degrees;
  • COOL- the air is cooled to +15 - 18 degrees. To change the temperature, you need to click on the down or up arrows;
  • DRY- dehumidification of air. At a stable temperature, humidity decreases;
  • FAN- adjusts the fan speed. Usually 3 speeds are set;
  • AUTO- all parameters are set automatically. Sometimes this mode is activated by a separate button. It can also be started from the air conditioner body, without a remote control;
  • SLEEP- quiet work at night;
  • SWING- a special mode of intensive ventilation of the room.

Battery replacement rules

In the description of the air conditioner remote control, a separate section is devoted to the correct use of the device:

  • It is necessary to change both batteries at once, install the same ones. To prevent the remote control settings from being lost, the replacement should be carried out as soon as possible;
  • In case of a long period of inactivity, it is advisable to remove the batteries from the remote control;
  • At standard use batteries last about 12 months. Some models indicate the need to replace the batteries. The fact that the batteries are weak is noticeable by the weakening of the display brightness and the slower response to commands;
  • Do not attempt to recharge disposable batteries.

Remote control

  • In order for the signal from the remote control to go to the receiving device, it is necessary to direct the LED towards the air conditioner. Any physical obstruction interferes with the signal transmission. Setting up the air conditioner remote control, as indicated by the instructions, is not at all difficult;
  • Protect the remote control from falling and getting wet;
  • The remote control works at a distance of no more than 8 meters;
  • If dust accumulates on the LED, it also interferes with the infrared beam. Therefore, the remote control must be periodically wiped with a dry cloth.

The same and is in water desired code to the remote control memory. As a rule, the remote control is attached, in which there are codes under different models air conditioners. There are two modes for setting up the remote control - automatic and manual.



Automatic mode can be used if you do not know which air conditioner you have or your model is not listed in the code table. To set up in the auto search mode, you need to take the remote control in your hand and point it at the air conditioner. Find the "SELECT" button on the remote control, press and hold it for 5 seconds, then release it.



The remote control will automatically send commands to the air conditioner and cycle through all available codes. In this case, the codes on the display of the remote control will flash and change. As soon as the correct code appears, you will hear sound signal from your unit and the air conditioner will turn on. At this moment, it is necessary to press any button on the remote control, the process of scanning the codes will be stopped.


Check the operation of the air conditioner with this code. If the commands are not executed correctly or some functions do not work, start the auto search for codes again until you find the code in which your air conditioner will work correctly.


Setting in manual mode takes less time. Find the code in the code table for your air conditioner model, there may be several of them. Press the "SELECT" button, while the code on the display of the remote control should blink once. Use the numeric buttons to enter the code into the remote control memory and press the "ENTER" button, the remote control is programmed.



Check how the commands are executed by the air conditioner. If the air conditioner does not work correctly, try entering the remaining codes one by one. You can also cycle through the codes using the "TEMP +" and "TEMP-" buttons.



After entering the correct code, the air conditioner control panel is ready for operation. All basic functions will be available to you. From the remote control it will be possible to select the operating mode of the air conditioner - this is cold, heat, ventilation, automatic mode. You can set the desired temperature, adjust the fan speed and select the direction of the air flow.

Galanz was founded back in 1978. Since that moment, the direction of activity has changed several times - production workshops for the manufacture of textiles were redesigned and supplemented with equipment for the production of household, and then climatic technology... The production of air conditioners of various lines was put on stream only in 2000. De Lux air conditioners were actively produced and sold. Already in 2003, the largest production complex in China was opened in the city of Zhunshan. Also, since 2005, a research center for the development of new climatic equipment has been successfully operating. This allows you to continuously improve the quality of products, improve and refine existing models of air conditioners and work on the production of new high-tech equipment.

Main lines of split systems

Today, under the Galans brand, several lines of climatic equipment are produced. This includes both relatively economical (budget) models with a standard set of functions and expensive split systems with rich functionality, stylish design and increased performance.

Galanz inverter split systems are suitable for installation within an apartment, house or office. Also, the operation of powerful models is acceptable in premises with a large area: halls of cafes or restaurants.

The device consists of several blocks and functional elements:

  • an external unit (mounted outside the room) where the compressor is located;
  • interior block made in a design style - placement directly in the room;
  • pipes;
  • electrical wires;
  • console mechanism.

The outdoor unit does most of the work of cooling or heating the air flow. It is equipped with a fan, devices for removing condensate, hot air. Indoor is required for air intake from the room and evaporation. It is located directly in the room and has a stylish design. Internal and external blocks are interconnected by means of wires and pipes. Control and setting of parameters are carried out remotely. For this, a remote control for the air conditioner of the selected model is used.

The installation of the air conditioner is carried out according to the standard scheme, only by experienced specialists. Preliminary determination of block placement is required. Depending on the model, the galanz split system can perform the following functions:

  • heating in cool weather (not lower than the temperature indicators specified in the instructions);
  • air cooling;
  • removal of excess moisture from the air;
  • moisturizing until certain indicators are reached;
  • air purification from dust particles;
  • removal of odors;
  • aromatization of the air;
  • ionization;
  • blowing off without heating or cooling.

The system can be controlled remotely using the remote control. The device works in automatic mode maintaining a favorable indoor climate. Most of the split systems, such as the Galanz Galaxy air conditioner, can turn off by a timer, and have a self-diagnosis function for malfunctions. By adjusting the position of the flaps, you can change the direction of air flows, and also use the system as a fan.

Comparison of characteristics of popular models

Galanz control panel and air conditioners manuals

Modern split systems are remotely controlled. In order to turn on the galaxy air conditioner or select a suitable mode, it is not at all necessary to approach the location of the indoor unit. It is enough just to use the remote control with the operating range specified in the manual.

Using the remote control, you will be able to perform the following actions:

  • enable or disable the split system;
  • adjust the operating mode;
  • adjust the temperature indicators maintained in automatic mode;
  • set a timer;
  • enable additional functions.


The remote control for the air conditioner is usually included in the basic kit and there is no need to purchase it separately. Application according to the information provided in the instructions. If you have any questions regarding device management, you can additionally study photo or video reviews.

Using the remote control makes the process of operating the split system even easier and more convenient. To change the mode, there is no need to be distracted from your usual activities or work - the range of action remote device pretty big. For proper operation it is necessary to monitor the battery charge level shown on the display. Also, the display can notify about malfunctions, breakdowns, since it is on it that the error code is displayed.

Galanz air conditioner error codes

The galanz air conditioner manual clearly describes all the requirements for the operation of the model. The conditions necessary for full-fledged operation, the limits of permissible temperatures are indicated here: at sharply negative temperatures (the restrictions are indicated in the induction specific model) split systems are not recommended for heating. The air will be heated in an enhanced mode, which will lead to an overload of the system and its failure. That is why it is so important to study before installation and operation. specifications devices.

Among the common breakdowns requiring immediate repair of the air conditioner are:

  • breakdown of the relay;
  • clogging of the drainage system;
  • insufficient filling of refrigerant, its shortage or excess;
  • no refrigerant entering the evaporator;
  • jammed compressor;
  • violation in the starting board;
  • breakdown of the thermostat.


It is far from always that a malfunction requires repair with the delivery of an air conditioner to service center... Often, it is enough to just get it working by replacing the filter or batteries in the remote control. The problem may lie in insufficient power supply. There may have been errors during the installation process. The main thing is to correctly determine the cause of the malfunction and eliminate it as soon as possible.

You can find out the exact cause of the breakdown and understand what exactly is wrong with the air conditioner by paying attention to the electronic inscription on the display. Majority modern models have the function of self-diagnosis of malfunctions. If the device supports this function, the display will show a code. Each individual code corresponds to a specific malfunction. The code method is very handy. It allows you to avoid lengthy diagnostics with the delivery of the device to a service center, which would take a lot of time. Air conditioner error codes are a simple and quick way to inform the master about the need for a certain type of repair work. Such a modern method of diagnostics (self-diagnostics of the system) reduces time and financial costs. However, this does not mean at all that the user will be able to solve the problem on his own without the participation of a professional. If you see a specific set of characters displayed on the electronic display, you need to contact the service center.